11
2017 Page 235 5IN2413 B
Appendix F: Monitoring Station Report Codes
Parameter Contact ID SIA Report Category
Alarms
Panic alarm 120 PA Urgent
Panic alarm restore 120 PH Urgent
Fire alarm 115 FA Urgent
Fire alarm restore 115 FH Urgent
Medical alarm 100 MA Urgent
Medical alarm restore 100 MH Urgent
Duress alarm 121 HA Urgent
Duress alarm restore 121 HH Urgent
Box tamper 137 TA Urgent
Box tamper restore 137 TR Urgent
Confirmed alarm 139 BV Urgent
Confirmed alarm restore 139 Urgent
Recent Close 459 Non- urgent
Main Troubles
Bell trouble 321 YA Non- urgent
Bell trouble restore 321 YH Non- urgent
Auxiliary failure 300 YP Non- urgent
Auxiliary restore 300 YQ Non- urgent
Bus failure 333 ET Non- urgent
Bus restore 333 ER Non- urgent
Low battery 302 YT Non- urgent
Low battery restore 302 YR Non- urgent
AC loss 301 AT Non- urgent
AC restore 301 AR Non- urgent
Clock not set 626 Non- urgent
Clock set 625 Non- urgent
False code 421 JA Non- urgent
False code restore 421 Non- urgent
Main phone trouble 351 LT Non- urgent
Main phone trouble restore 351 LR Non- urgent
RF Jamming 344 XQ Non- urgent