11
2017 Page 125 5IN2413 B
Quick Keys Parameter Default Range
ZZZ
Arm/Disarm
No
Defines the operation of the LEDs and anti-masking detections while
the detector is armed.
Active IR AM and Proximity AM (anti-masking) is enabled.
LEDs behave according to the LEDs parameter definition.
YES – Active IR AM and Proximity AM (anti-masking) is disabled
LEDs are disabled.
ZZZ
Green Line
Yes
This feature defines the activation of the microwave channel while the
system is disarmed.
NO - Green Line feature is disabled. MW is constantly activated.
YES - Green Line feature is enabled. This option conforms to
environmentally friendly standards by avoiding surplus emission.
ZZZ
Sway
No
This option allows the recognition and immunity of swaying objects
in a known pattern.
NO - Sway is disabled.
YES - Sway is enabled.
Bus Zone: Seismic
Quick Keys Parameter Default Range
ZZZ
Sensitivity
Normal
Defines the Seismic sensitivity of the detector.
LEVEL 1, LEVEL 2, LEVEL 3, LEVEL 4, LEVEL 5, LEVEL 6,
LEVEL 7, LEVEL 8
ZZZ
Interference Time
10 Seconds 10, 20, 40, or 80 sec
Defines the moving window of time in which the vibration signal is
accumulated (integrated). Detection is triggered when the
accumulated signal reaches a threshold value. Longer time causes
higher detection sensitivity.
ZZZ
Explosion
Sensitivity
Low
Defines the explosion sensitivity of the detector.
LOW HIGH