11
2017 Page 126 5IN2413 B
Quick Keys Parameter Default Range
ZZZ
Temperature
Sensitivity
Off
Defines the sensitivity to temperature change.
OFF ON
ZZZ
Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a
self-test trouble is created
REMOTE (Manual) - The remote self-test is performed by the
system when a user manually selects the Diagnostics option from the
Maintenance menu via the ProSYS Plus User Functions menu
LOCAL (automatic) - Once an hour, the detector automatically
checks that the detector’s channels are functioning properly.
ZZZ
LEDS
On
Defines the LEDS operation mode.
OFF - Disables the LEDS operation.
ON – Enables the LEDS operation
ZonesParametersBy CategoryAdvancedWireless Zones Configuration
Quick Keys Parameter Default Range
Wireless Zones Configuration
The Wireless Zone Parameters menu contains parameters that enable
you to program the special parameters of a 1-way or 2-way wireless
zone. The options are determined according to the wireless detector
type. For example:
• 2-Way WatchOUT: A dual technology outdoor detector with
signal processing based on two Passive Infrared (PIR) channels
and two Microwave (MW) channels.
• 2-Way Magnet: Contact detector (x73) – models include shutter
and universal
• 2-Way IR Beams
• 1 & 2-Way Smoke detector
• 2-Way PIR
• Also Shock, Flood, Gas, CO, and Curtain detectors
Use the instructions below to set parameters for the relevant wireless