a. [Labels]: Give the zone a descriptive “label” by typing over the default
“ZONE” (see Designating Labels, page 49), and then press OK .
b. [Partitions]: To select partitions (up to 32) to associate with the zone, scroll
to the partitions, which are grouped in blocks: the first block contains
partitions 01—08 (the default) if that is what was enabled. If additional
partitions were enabled, scroll to all the blocks (of ten) they are located in:
block 01—10, 11—20, 21—30, and 31—32. In each block, enter the relevant
partition number/s (each will display as P=#) and then before pressing OK,
scroll to the next blocks and do the same. When finished, press OK.
c. [Group]: A group is a specific area (zone) that can be armed within a
specific partition – up to 4 groups [A—D] maximum per each partition. For
each group letter, toggle between Y (select) and un-select, then scroll to the
next group letter, if needed. When finished press OK.
d. [Zone Type]: Scroll to select the zone type (35 zone types), then press OK.
e. {Arm Sound]: Scroll to select an arming sound, and then press OK.
Options: silent, bell only, buzzer only, bell+buzzer, door chime.
f. [Stay (Partial Arm) Sound]: Scroll to select a partial arming sound, then
press OK. Options: silent, bell only, buzzer only, bell+buzzer, door chime.
g. [Disarm Sound]: Scroll to select the disarming arm sound for this zone, and
then press OK. Options: silent, door chime.
h. [Terminate]: For wired relay-detector zones only. Scroll to select the zone
termination type, then press OK. Options: NC, EOL, DEOL, N/O, TEOL.
i. [Response]: Scroll to select zone response time, then press OK. Options:
NORMAL (400 ms), LONG (1 sec.), FAST (10 ms), and E. FAST (1 ms).
4. Press OK to go to the next zone, and repeat the procedure for all other zones.
Defining Zone Parameters using the “By Category” Option
For a specific parameter type, this lets you to define it accordingly for multiple
zones (as you go from one to another, scrolling through all zones in the system).
To define zone parameters using the By-Category option:
1. From the installer Programming menu go to: 2 1 2 (Zones Parameters
By Category).
2. Scroll to arrive to the parameters and their respective options to modify.
Parameters: Label, Partition, Type, Sound, Termination, Loop Response,
Advanced. Press OK ( ) to confirm after each selection. Use the numeric keys
to enter the zone number (or numeric values) where needed.