11
2017 Page 52 5IN2413 B
Keypad Timeout
When in installer Programming, if no entry is made to a keypad after the pre-
defined time period (see installer Programming menu), it will beep and display
TIME OUT, HIT ANY KEY. Press any key to stop the beeping, then
re-enter your installer code to get back in the installer Programming menu.
Viewing & Updating Zones & Defining Partitions after Initialization
After system initialization, you can view the total number of enabled zones, define
partitions, and also manually update the system with any additional zone licenses
purchased which are activated using HandyApp -- this can be useful, for example,
if during system initialization the automatic connection to the Cloud fails.
To view enabled zones after system initialization:
1. Enter your installer code (default is 1111).
2. From the installer Programming menu, go to: 1 5 7 (System Settings
Licenses), and then press OK ( ).
3. Scroll to 1) View Licenses to view the total number of enabled zones (the default
of 64 zones plus any additional zone licenses purchased which are activated
using HandyApp), and then press OK.
NOTE: The panel must be connected to the Cloud in order to display the total
number of enabled zones, otherwise only the default number (64 provided
zones) will display.
To update the system with new zone licenses after system initialization:
• To manually update the system with the new zone license information (for any
new zone licenses that were purchased which are activated using HandyApp),
scroll to 2) D/L Licenses and then configure the Cloud-connectivity
parameters.
To define the partition quantity after system initialization:
1. Go to: 1 5 8 (System Settings Partition Qty), and then press OK ( );
MAXIMUM PARTITIONS? 08 (08—32) displays.
2. Enter the maximum number of partitions to enable in the system – the default is
08 (meaning up to 8), but up to 32 can be selected. If you want more than 8
partitions, enter the number.
3. Press OK.