2017 Page 53 5IN2413 B
Step 3: Allocating and Configuring Installed
Components
Perform an Auto-Setting scan to locate, allocate, and configure all installed
communication modules & bus devices.
NOTE: The automatic setting/un-setting function is not in compliance with
EN50131-3.
Auto-Setting Scan for Communication Modules & Bus Devices
Performing an Auto-Setting scan finds all installed communication modules and
bus devices connected in the system. As you view the results, you allocate
(“enable”) each, and then you can configure their settings now, or later during
installer programming. For configuration details see Manually Allocating &
Configuring Communication Modules on page 55, and see Manually Allocating &
Configuring other Modules and Bus Devices on page 57.
To perform an Auto-Setting system scan:
1. Upon accessing the installer Programming mode after system initialization,
when BUS DEVICE: 1)AUTOMATIC displays (Auto Settings feature), press OK
( ); BUS SCANNING displays while scanning, until the results display – first
are the communication modules that were found, followed by the bus devices.
2. Press OK to enable the first communication module displayed, and keep
pressing OK to progress through its parameter configuration screens (which
you can configure now or later during installer programming).
3. Press OK again to advance to the next communication module (if applicable) –
followed by all other bus devices found, and again enable/configure for each.
4. Make sure all the communication modules/bus devices found in the scan match
all the communication modules/bus devices physically connected in the system.
When BUS Device: 1)Automatic displays again and the panel beeps, it indicates
you have finished the Auto-Setting scan.
5. Now you can perform a Bus Test to ensure good communication between the
allocated bus devices and the main panel (see Performing a Bus Test, page 54).
NOTE: If you subsequently add more bus-connected devices, you can either
allocate and configure them manually, or repeat the Auto-Setting system scan at:
Programming menu 7) Install 1)BUS Device BUS Device: 1)Automatic