11
2017 Page 121 5IN2413 B
Quick Keys Parameter Default Range
ZZZ
Arm/Disarm
No
Defines the operation of the anti-masking detection while the detector
is armed or disarmed
..
NO – While armed or disarmed, anti-mask behaves according to
the setting defined in quick keys ZZZabove.
YES – While armed, anti-mask is disabled. When detector is
disarmed Anti-mask behaves according to the settings defined in
quick keys
ZZZ.
ZZZ
Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a
self-test trouble is created
REMOTE (Manual) - The remote self-test is performed by the
system when a user manually selects the Diagnostics option from the
Maintenance menu via the ProSYS Plus User Functions menu
LOCAL (automatic) - Once an hour, the detector automatically
checks that the detector’s channels are functioning properly.
Bus Zone: iWISE QUAD Grade 2
Quick Keys Parameter Default Range
ZZZ
LEDS
On
Defines the LEDS operation mode.
OFF - Disables the LEDS operation.
ON - Enables the LEDS operation
ZZZ
PIR Sensitivity
High
Defines the PIR sensitivity of the detector.
LOW HIGH
ZZZ
Self Test
Remote
Used to test the detection technologies. In the event of a failed test,
a self-test trouble is created
REMOTE (Manual) - The remote self-test is performed by the
system when a user manually selects the Diagnostics option from
the Maintenance menu via the ProSYS Plus User Functions menu
LOCAL (automatic) - Once an hour, the detector automatically
checks that the detector’s channels are functioning properly