Quick Keys Parameter Default Range

Listen In
120 sec
1–255 seconds
The time duration for the monitoring station to listen in and perform
voice alarm verification. After this period the system hang up the
line.
The monitoring station can expand the listen in time during the
conversation by pressing the digit “1” on the telephone (for a
repeatable two minute extension). In this case, the Listen In time will
reset and start over again.
Pressing “2” during Listen In time will switch to Talk mode. Pressing
*” during Listen In time will end the call.

Confirmation
These confirmation times relate to the zone's sequential confirmation
(see
) - Alarm Confirm, page 134).

Confirm Start
(Confirm delay time)
000
1
120 minutes
Specifies that the system cannot start a sequential confirmation
process until the timer has expired. This time starts when the system
has been armed and will prevent confirmed alarms being generated
in situations when a person has been accidentally locked in the
building.

Confirm Time
(Confirmation Time
Window)
030
30
60 minutes
Specifies a time period that starts when an intrusion alarm is
triggered for the first time. If a second intrusion alarm is triggered
before the end of the time period (the "confirmation time window"),
the system will then send a "confirmed" alarm notification to the
monitoring station.