Fernsteuerbefehle
R&S
®
RTB2000
484Bedienhandbuch 1333.1611.03 ─ 05
WGENerator:MODulation:TYPE...................................................................................... 486
WGENerator:MODulation:AM:FREQuency....................................................................... 487
WGENerator:MODulation:AM:DEPTh...............................................................................487
WGENerator:MODulation:FM:FREQuency........................................................................487
WGENerator:MODulation:FM:DEViation...........................................................................487
WGENerator:MODulation:ASK:FREQuency......................................................................488
WGENerator:MODulation:ASK:DEPTh.............................................................................488
WGENerator:MODulation:FSK:HFREquency.................................................................... 488
WGENerator:MODulation:FSK:RATE............................................................................... 488
WGENerator:MODulation:RAMP:POLarity........................................................................488
WGENerator:NOISe:ABSolute.........................................................................................488
WGENerator:NOISe:RELative.........................................................................................488
WGENerator:OUTPut:DESTination.................................................................................. 489
WGENerator:OUTPut:LOAD........................................................................................... 489
WGENerator:OUTPut[:ENABle]....................................................................................... 489
WGENerator:SWEep:FEND............................................................................................ 489
WGENerator:SWEep:FSTart........................................................................................... 489
WGENerator:SWEep:TIME............................................................................................. 489
WGENerator:SWEep:TYPE............................................................................................ 489
WGENerator:SWEep[:ENABle]........................................................................................490
WGENerator:FUNCtion <Function>
Selects the function to be generated.
Parameter:
<Function> DC | SINusoid | SQUare | PULSe | TRIangle | RAMP | SINC |
ARBitrary | EXPonential
WGENerator:VOLTage <Amplitude>
Defines the amplitude value (peak-to-peak value) of the selected generator function.
Parameter:
<Amplitude> Numeric value
Bereich: 6.0000E-02 bis 6.00000E+00
*RST: 5.0000E-01
Std.-einheit: Vpp
WGENerator:VOLTage:OFFSet <Offset>
Sets the DC offset of the selected generator function.
Parameter:
<Offset> Numeric value
Bereich: -3.00000E+00 bis 3.00000E+00
*RST: 0.00E+00
Std.-einheit: V