7K Chapter 15
15-2
Select Logic Outputs
Controls the seven Logic Outputs.
List the outputs to be controlled by entering any combination of digits 1–7.
Command Form:
Command Form
Select Logic Outputs Latched OFF (PW) 71 (list the outputs) *
Select Logic Outputs Latched ON (PW) 70 (list the outputs) *
Select Logic Outputs Momentary OFF (PW) 73 (list the outputs) *
Select Logic Outputs Momentary ON (PW) 72 (list the outputs) *
Acknowledgment: Sends OK
Errors:
Error Meaning
? err 2 illegal digit entered
Default Condition: All Logic Outputs are OFF (disabled)
Examples:
There are several examples for logic outputs. To turn ON logic output 1, enter:
(PW) 70 1 *
To turn ON logic output 2, enter:
(PW) 70 2 * (Logic output 1 is still ON.)
To turn OFF both logic outputs, enter:
(PW) 71 1 2 *
To momentarily turn ON logic output 1, enter:
(PW) 72 1 *
To momentarily turn ON both logic outputs, enter:
(PW) 72 1 2 *
If logic output 2 is ON, you may momentarily turn it OFF by entering:
(PW) 73 2 *