7K • Chapter 16
16-2
Select Receiver Activity-Triggered Macros
Select Receiver Post-Activity Timers
Allows the programmer to execute macros based on activity
detected by the receivers.
Receiver Post-Activity Timers delay the macro execution for a
programmable length of time after last activity.
• Each receiver has its own Start-of-Activity Macro, Post-Activity Macro, and
Post- Activity Timer.
• The Receiver Post-Activity Timer starts each time receiver activity ends.
When the timer expires, the macro associated with the receiver is executed.
The timers require two data digits representing the delay. “00-99” equals
0.0-9.9 minute delay.
• These macros execute based solely on receiver activity, and act
independently of the transmitter paths that the receivers drive.
• Be sure to set the corresponding receiver access mode for Receiver 1, 2,
and 3 using the Select Path Access Mode commands for Rx1-to-Tx1, Rx2-
to-Tx1, and/or Rx3-to-Tx1 on page 13-4.
Command Form:
Command Form Data Digit
Select RX1 Start-of-Activity Macro (PW) 26 67 (macro name) * not applicable
Select RX1 Post-Activity Macro (PW) 26 68 (macro name) * not applicable
Select RX2 Start-of-Activity Macro (PW) 26 69 (macro name) * not applicable
Select RX2 Post-Activity Macro (PW) 26 70 (macro name) * not applicable
Select RX3 Start-of-Activity Macro (PW) 26 71 (macro name) * not applicable
Select RX3 Post-Activity Macro (PW) 26 72 (macro name) * not applicable
Select RX1 Post-Activity Timer (PW) 99 00 xx * xx = duration = 00–99
= 0.0–0.0 minutes
Select RX2 Post-Activity Timer (PW) 99 01 xx * xx = duration = 00–99
= 0.0–0.0 minutes
Select RX3 Post-Activity Timer (PW) 99 02 xx * xx = duration = 00–99
= 0.0–0.0 minutes
Acknowledgment: Sends OK