Remote Base Interface
21-29
Select RBI-1 Number of User Function Outputs
Selects the number of RBI-1 User Function Outputs to be included
in the group.
Enter a number from 0 to 8 to define how many outputs are to be controlled
as a group.
The group always starts at UF-1.
Programmer’s note: UF-8 is the Most Significant Bit (MSB); UF-1 is the
Least Significant Bit (LSB).
Command Form:
Command Form
Select RBI-1 Number of User Function
Outputs
(PW) 39 90 (number of outputs) *
Acknowledgment: Sends OK
Errors:
Error Meaning
OFF remote base is disabled
? err 1 wrong number of digits entered
? err 2 illegal digit entered
Default Condition: All 8 outputs are included in the group.
Example:
To set the number of outputs in the group to 6, enter the following:
(PW) 39 90 6 *