7K • Chapter 18
18-4
Select Repeater Activity-Triggered Macros
Select Repeater Activity Counter/Timer
Allows the programmer to execute macros based on the activity of
the repeater.
Sets the Repeater Activity Counter/Timer (both the Event Count
and the Duration).
• No data digits are required for the macros.
• Select the Repeater Activity Counter/Timer (Event Count) using 1-digit, 0–9.
Setting the counter to 0 (zero) means that the Post-Activity Macro will
execute each activity cycle. Setting the counter to 1 means that the post-
activity macro will execute every other activity cycle, and so on. Setting the
counter to 9, therefore, means that the post- activity macro will execute
every 10th cycle.
• Select the Repeater Activity Counter/Timer (Duration) using 2 digits
representing the delay. (00–99) equals (0.0–9.9) minute delay.
Command Form:
Command Form Data Digit
Select Repeater Start-of-Activity Macro (PW) 26 14 (macro
name) *
not applicable
Select Repeater Post-Activity Macro (PW) 26 15 (macro
name) *
not applicable
Select Repeater Activity Counter/Timer (PW) 45 x yy* x = (event count) =
(0–9)
y = (duration) =
(00–99) = (0.0–9.9)
minute delay
Acknowledgment: Sends OK
Errors:
Error Meaning
? err 1 wrong number of digits entered
? err 2 illegal digit entered
Default: No Macros are assigned; Event Count is 0; Duration is 1.0 minutes