EasyManua.ls Logo

S-COM 7K - Select Repeater Action-Triggered Macros

Default Icon
400 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Repeater Functions
18-11
Select Repeater Action-Triggered Macros
Allows the programmer to execute macros based on repeater
activity.
Macros can be executed based on receiver activity, receiver inactivity and
when a courtesy message is sent.
Enter the password, the 4-digit root number, and the 4-digit name of the
macro you wish to have executed at the transition, and the (*).
If the macro name has fewer than 4 digits, enter leading zeros.
If you wish to prevent a macro from being executed that was previously
assigned, enter just the password, the 4-digit root number, and the (*).
Command Form:
Command Form
Assign Macro to Any-Receiver-Active (PW) 26 11 (macro name) *
Assign Macro to All-Receivers-Inactive (PW) 26 09 (macro name) *
Assign Macro to Courtesy Message (PW) 26 10 (macro name) *
Assign Macro to Dropout Message (PW) 26 08 (macro name) *
Assign Macro to Repeater Timeout (PW) 26 18 (macro name) *
Assign Macro to Return-From-Repeater-
Timeout
(PW) 26 19 (macro name) *
Acknowledgment: Sends OK
Errors:
Error Meaning
? err 1 wrong number of digits entered
? err 2 illegal digit entered
Default Condition: No macros assigned.