Remote Base Interface
21-5
Select Remote Base Access- and
Dump-Triggered Macros
Assigns macros to be executed upon accessing or dumping the
remote base.
• Enter the password, the 4-digit root number, and the 4-digit name of the
macro you wish to have executed at the transition, and the (*).
• If the macro name has fewer than 4 digits, enter leading zeros.
• If you wish to prevent a macro from being executed that was previously
assigned, enter just the password, the 4-digit root number, and the (*).
Command Form:
Command Form
Select Remote Base Access-Triggered
Macro
(PW) 26 91 (macro name) *
Select Remote Base Dump-Triggered Macro (PW) 26 90 (macro name) *
Acknowledgment: Sends OK
Errors:
Error Meaning
? err 1 wrong number of digits entered
? err 2 illegal digit entered
Default Condition: No macros assigned.
Example:
These commands make the remote base interface much more flexible. For
example, when a user enters the Access Remote Base command, a macro can
be executed to enable the controller link paths, power up a remote base radio,
set the frequency, select an antenna, and rotate the antenna to point in a
particular direction; when a user enters the Dump Remote Base command, a
macro can be executed to disable the controller link paths and turn off the
power to the remote base radio.