7K • Chapter 21
21-8
Enable/Disable Access to the Remote Base
A flexible control scheme controls access to the remote base.
• Turns ON or OFF the remote base interface.
• Enter 1 digit: 0 for OFF (disabled), 1 for ON (enabled).
• Remote Base Enable #1 is intended to be used by the Control Operator as
a master enable/disable of the remote base interface.
• Remote Base Enable #2 is intended to be used by the Time-of-Day
Scheduler to control the times when the remote base interface may be
used.
• Remote Base Enable #3 is intended to be used by the Control Operator to
override the Time-of-Day Scheduler to activate the remote base interface at
a time of day when the interface would be normally disabled.
• If the Time-of-Day Scheduler is not going to be utilized, only Remote Base
Enable #1 needs to be manipulated by the Control Operator.
• Programmer’s note: the remote base is enabled when the following
equation evaluates to TRUE: EN1 AND (EN2 OR EN3).
Command Form:
Command Form Data Digit
Enable/Disable Remote Base Enable #1 (PW) 63 71 x * 0 = OFF (disabled)
1 = ON (enabled)
Enable/Disable Remote Base Enable #2 (PW) 63 72 x * 0 = OFF (disabled)
1 = ON (enabled)
Enable/Disable Remote Base Enable #3 (PW) 63 73 x * 0 = OFF (disabled)
1 = ON (enabled)
Acknowledgment: Sends OK
Errors:
Error Meaning
? err 1 wrong number of digits entered
Default Condition: Enable #1 is OFF; Enable #2 is ON; Enable #3 is OFF.