7K • Chapter 17
17-12
Select Transmitter Minimum Unkey Delay
Programs the minimum amount of time for a transmitter to unkey.
• A Transmitter 1 Minimum Unkey Delay can be programmed from 0 to 655.3
seconds.
• A Transmitter 2 Minimum Unkey Delay can be programmed from 0 to 655.3
seconds.
• Enter the timeout value as 1, 2, 3, or 4 digits, leading zeroes are not
required.
• A programmed Minimum Unkey Delay will not be present unless it is
enabled using the Enable/Disable Transmitter Minimum Unkey Delay
command (see page 17-11).
Command Form:
Command Form Data Digit
Select Tx1 Minimum Unkey Delay (PW) 49 98 xxxx * from table below
Select Tx2 Minimum Unkey Delay (PW) 49 99 xxxx * from table below
Data Digit Explanation
xxxx = 0000-6553 seconds in 0.1 second increments from 0.0 to
655.3 seconds as 1, 2, 3, or 4 digits
Acknowledgment: Sends OK
Errors:
Error Meaning
? err 1 wrong number of digits entered
? err 2 invalid timer or seconds parameter
Default Condition: None.
Example:
To set the Transmitter 1 Minimum Unkey Delay to 0.4 second, enter the command:
(PW) 49 98 4 *
To set the Transmitter 2 Minimum Unkey Delay to 5.0 seconds, enter the command:
(PW) 49 99 50 *