EasyManua.ls Logo

S-COM 7K - Enable;Disable End-of-Transmission Command Execution

Default Icon
400 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7K Chapter 16
16-6
Enable/Disable End-of-Transmission
Command Execution
Allows commands to be terminated by ending the transmission
(releasing user PTT). This is in addition to the usual (*) character.
The (*) character will terminate a command in any case.
You may enable or disable this feature separately for each receiver.
If this feature is enabled, the command will be executed 0.25 seconds after
the transmission ends.
Enter one digit, 0 for OFF (disabled), 1 for ON (enabled).
Command Form:
Command Form Data Digit
Enable/Disable End-of-Transmission
Command Execution for RX1
(PW) 63 57 x * 0 = OFF (disabled)
1 = ON (enabled)
Enable/Disable End-of-Transmission
Command Execution for RX2
(PW) 63 58 x * 0 = OFF (disabled)
1 = ON (enabled)
Enable/Disable End-of-Transmission
Command Execution for RX3
(PW) 63 59 x * 0 = OFF (disabled)
1 = ON (enabled)
Acknowledgment: Sends OK
Errors:
Error Meaning
? err 1 wrong number of digits entered
? err 2 illegal digit entered
Default condition: End-of-Transmission Command Execution is OFF
(disabled) for all receivers; (*) character required to terminate all commands

Table of Contents