7K • Chapter 16
16-6
Enable/Disable End-of-Transmission
Command Execution
Allows commands to be terminated by ending the transmission
(releasing user PTT). This is in addition to the usual (*) character.
• The (*) character will terminate a command in any case.
• You may enable or disable this feature separately for each receiver.
• If this feature is enabled, the command will be executed 0.25 seconds after
the transmission ends.
• Enter one digit, 0 for OFF (disabled), 1 for ON (enabled).
Command Form:
Command Form Data Digit
Enable/Disable End-of-Transmission
Command Execution for RX1
(PW) 63 57 x * 0 = OFF (disabled)
1 = ON (enabled)
Enable/Disable End-of-Transmission
Command Execution for RX2
(PW) 63 58 x * 0 = OFF (disabled)
1 = ON (enabled)
Enable/Disable End-of-Transmission
Command Execution for RX3
(PW) 63 59 x * 0 = OFF (disabled)
1 = ON (enabled)
Acknowledgment: Sends OK
Errors:
Error Meaning
? err 1 wrong number of digits entered
? err 2 illegal digit entered
Default condition: End-of-Transmission Command Execution is OFF
(disabled) for all receivers; (*) character required to terminate all commands