7K • Chapter 21
21-6
Select (Review) Remote Base Off Message
This message is sent over the repeater transmitter when the remote
base is off.
• The Remote Base Off Message is sent when a User Function command
has been executed and the remote base has not been enabled (see
page 21-7).
• The message may be a combination of message types including CW,
beeps, page tones, speech, etc.
• The maximum size of the message is 50 bytes (50 2-digit codes). You must
count the control characters. Therefore, any message could have 46 CW
characters, 23 synthesized speech words, etc.
• To delete a message, enter the password, the 4-digit root number, and the
(*); do not enter any message.
• If this message is not programmed, the default CW message will be sent
only when Command Responses are enabled.
Command Form:
Command Form Default
Select Remote Base Off Message (PW) 31 60 (message) * OFF in CW
Review Remote Base Off Message (PW) 34 60 * none
Acknowledgment: Sends OK
Errors:
Error Meaning
? err 1 wrong number of digits entered
? err 2 illegal digit entered
Default Condition: The default CW message is sent only if Command
Responses are enabled.
Example:
To program the Remote Base Off Message to say “Remote Base Off”, enter
the command:
(PW) 31 60 9960 0000 0418 0049 0355 *