Remote Base Interface
21-9
Example:
The Control Operator can enable the remote base interface by entering:
(PW) 63 71 1 *
The Control Operator can disable the remote base interface by entering:
(PW) 63 71 0 *
To have the Scheduler control remote base access, define Scheduler setpoints
to disable the remote base interface during afternoon drive times (4:00 P.M.
through 6:30 P.M.) Monday through Friday. This requires macros to be
executed by the Scheduler.
First, define macros containing the commands to enable and disable the
remote base interface using Enable #2:
(PW) 20 9002 (PW) 63 72 0 * ; disable remote base
(PW) 20 9003 (PW) 63 72 1 * ; enable remote base
Then, define Scheduler setpoints to execute these macros:
(PW) 28 00 9002 99 32 16 00 * ; disable at 4 PM
(PW) 28 01 9003 99 32 18 30 * ; enable at 6:30 PM