Ctrl Command z_out
Support status This RTC
®
3/RTC
®
4 command is not supported by the RTC
®
5.
RTC
®
4
RTC
®
5 For setting the Z value in a 3-axis scan system, the command set_defocus (see page 414)
can be used (only together with an RTC
®
5 with enabled 3D option). After
load_z_table(0.0, 1.0, 0.0), set_defocus(
Z
) has the same effect as z_out(
Z
) (also see
set_offset_xyz).