Siemens RUGGEDCOM ROS v4.3 - IP Interface, Gateway, and Network Service Configuration

Siemens RUGGEDCOM ROS v4.3
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3
Device Management
RUGGEDCOM ROS
User Guide
84 Resetting Ethernet Ports
Section3.6.11
Resetting Ethernet Ports
At times, it may be necessary to reset a specific Ethernet port, such as when the link partner has latched into an
inappropriate state. This is also useful for forcing a re-negotiation of the speed and duplex modes.
To reset a specific Ethernet port(s), do the following:
1. Navigate to Ethernet Ports» Reset Port(s) . The Reset Port(s) form appears.
1
2
Figure35:Reset Port(s) Form
1.Ports 2.Apply Button
2. Select one or more Ethernet ports to reset.
3. Click Apply. The selected Ethernet ports are reset.
Section3.7
Managing IP Interfaces
RUGGEDCOM ROS allows one IP interface to be configured for each subnet (or VLAN), up to a maximum of 255
interfaces. One of the interfaces must also be configured to be a management interface for certain IP services,
such as DHCP relay agent.
Each IP interface must be assigned an IP address. In the case of the management interface, the IP address type can
be either static, DHCP, BOOTP or dynamic. For all other interfaces, the IP address must be static.
CAUTION!
Configuration hazard – risk of communication disruption. Changing the ID for the management VLAN
will break any active Raw Socket TCP connections. If this occurs, reset all serial ports.
CONTENTS
Section3.7.1, “Viewing a List of IP Interfaces”
Section3.7.2, “Adding an IP Interface”