Chapter 3
Device Management
RUGGEDCOM ROS
User Guide
62 Viewing a List of Remote Syslog Servers
32
1
Figure14:Remote Syslog Client Form
1.UDP Port 2.Apply Button 3.Reload Button
2. Configure the following parameter(s) as required:
Parameter Description
UDP Port Synopsis:  1025 to 65535 or { 514 }
Default:  514
The local UDP port through which the client sends information to
the server(s).
3. Click Apply.
Section3.5.4.2
Viewing a List of Remote Syslog Servers
To view a list of known remote syslog servers, navigate to Administration» Configure Syslog» Configure
Remote Syslog Server . The Remote Syslog Server table appears.
Figure15:Remote Syslog Server Table
If remote syslog servers have not been configured, add the servers as needed. For more information, refer to
Section3.5.4.3, “Adding a Remote Syslog Server” .