Chapter 3
Device Management
RUGGEDCOM ROS
User Guide
98 Viewing a List of RMON Alarms
Figure52:The Alarm Process
There are two methods to evaluate a statistic in order to determine when to generate an event: delta and
absolute.
For most statistics, such as line errors, it is appropriate to generate an alarm when a rate is exceeded. The
alarm defaults to the delta measurement method, which examines changes in a statistic at the end of each
measurement period.
It may be desirable to alarm when the total, or absolute, number of events crosses a threshold. In this case, set the
measurement period type to absolute.
CONTENTS
Section3.10.2.1, “Viewing a List of RMON Alarms”
Section3.10.2.2, “Adding an RMON Alarm”
Section3.10.2.3, “Deleting an RMON Alarm”
Section3.10.2.1
Viewing a List of RMON Alarms
To view a list of RMON alarms, navigate to Ethernet Stats» Configure RMON Alarms . The RMON Alarms table
appears.
Figure53:RMON Alarms Table
If alarms have not been configured, add alarms as needed. For more information, refer to Section3.10.2.2,
“Adding an RMON Alarm” .

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROS v4.3 and is the answer not in the manual?

Siemens RUGGEDCOM ROS v4.3 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROS v4.3
CategoryWireless Router
LanguageEnglish

Related product manuals