Figure57:RMON Alarms Form
1.Index Box 2.Variable Box 3.Rising Thr Box 4.Falling Thr Box 5.Value Box 6.Type Options 7.Interval Box 8.Startup
Alarm List 9.Rising Event Box 10.Falling Event Box 11.Owner Box 12.Apply Button 13.Delete Button 14.Reload Button
3. Click Delete.
Section3.10.3
Managing RMON Events
Remote Monitoring (RMON) events define behavior profiles used in event logging. These profiles are used by
RMON alarms to send traps and log events.
Each alarm may specify that a log entry be created on its behalf whenever the event occurs. Each entry may also
specify that a notification should occur by way of SNMP trap messages. In this case, the user for the trap message
is specified as the Community.
Two traps are defined: risingAlarm and fallingAlarm.