EasyManua.ls Logo

Siemens RUGGEDCOM ROS v4.3 - Adding an RMON Alarm

Siemens RUGGEDCOM ROS v4.3
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RUGGEDCOM ROS
User Guide
Chapter 3
Device Management
Adding an RMON Alarm 99
Section3.10.2.2
Adding an RMON Alarm
To add an RMON alarm, do the following:
1. Navigate to Ethernet Stats» Configure RMON Alarms . The RMON Alarms table appears.
1
Figure54:RMON Alarms Table
1.InsertRecord
2. Click InsertRecord. The RMON Alarms form appears.
14
12
13
1
2
3
4
5
6
7
8
9
10
11
Figure55:RMON Alarms Form
1.Index Box 2.Variable Box 3.Rising Thr Box 4.Falling Thr Box 5.Value Box 6.Type Options 7.Interval Box 8.Startup
Alarm List 9.Rising Event Box 10.Falling Event Box 11.Owner Box 12.Apply Button 13.Delete Button 14.Reload Button
3. Configure the following parameter(s) as required: