EasyManuals Logo

Siemens RUGGEDCOM ROS v4.3 User Manual

Siemens RUGGEDCOM ROS v4.3
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
Chapter 3
Device Management
RUGGEDCOM ROS
User Guide
54 Restoring Factory Defaults
Parameter Description
The total size of RAM in the system.
RAM Free Synopsis:  0 to 4294967295
The total size of RAM still available.
RAM Low Watermark Synopsis:  0 to 4294967295
The size of RAM that have never been used during the system
runtime.
Temperature Synopsis:  -32768 to 32767 C
The temperature on CPU board.
Free Rx Bufs Synopsis:  0 to 4294967295
Free Rx Buffers.
Free Tx Bufs Synopsis:  0 to 4294967295
Free Tx Buffers.
Section3.3
Restoring Factory Defaults
The device can be completely or partially restored to its original factory default settings. Excluding groups of
parameters from the factory reset, such as those that affect basic connectivity and SNMP management, is useful
when communication with the device is still required during the reset.
The following categories are not affected by a selective configuration reset:
• IP Interfaces
• IP Gateways
• SNMP Users
• SNMP Security to Group Maps
• SNMP Access
• RUGGEDCOM Discovery Protocol™ (RCDP)
In addition, the following categories are not affected by a full or selective configuration reset:
• Time Zone
• DST Offset
• DST Rule
To restore factory defaults, do the following:
1. Navigate to Diagnostics» Load Factory Defaults . The Load Factory Defaults form appears.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROS v4.3 and is the answer not in the manual?

Siemens RUGGEDCOM ROS v4.3 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROS v4.3
CategoryWireless Router
LanguageEnglish

Related product manuals