Chapter 3
Device Management
RUGGEDCOM ROS
User Guide
86 Adding an IP Interface
7
8
1
2
3
4
5
6
9
Figure38: IP Interfaces Form
1.Type Options 2.ID Box 3.Mgmt Options 4.IP Address Type Box 5.IP Address Box 6.Subnet Box 7.Apply Button
8.Delete Button 9.Reload Button
3. Configure the following parameter(s) as required:
NOTE
The IP address and mask configured for the management VLAN are not changed when resetting all
configuration parameters to defaults and will be assigned a default VLAN ID of 1. Changes to the
IP address take effect immediately. All IP connections in place at the time of an IP address change
will be lost.
Parameter Description
Type Synopsis:  { VLAN }
Default:  VLAN
Specifies the type of the interface for which this IP interface is
created.
ID Synopsis:  1 to 4094
Default:  1
Specifies the ID of the interface for which this IP interface is
created. If the interface type is VLAN, this represents the VLAN ID.
Mgmt Synopsis:  { No, Yes }
Default:  No
Specifies whether the IP interface is the device management
interface.
IP Address Type Synopsis:  { Static, Dynamic, DHCP, BOOTP }
Default:  Static
Specifies whether the IP address is static or is dynamically
assigned via DHCP or BOOTP>. The Dynamic option automatically
switches between BOOTP and DHCP until it receives a response
from the relevant server. The Static option must be used for non-
management interfaces.
IP Address Synopsis:  ###.###.###.### where ### ranges from 0 to 255
Default:  192.168.0.1

Table of Contents