RUGGEDCOM ROS
User Guide
Chapter 1
Introduction
Available Services by Port 11
Services Port Number
Service Enabled/
Disabled
Access Authorized Note
management
interfaces.
HTTP TCP/80 Enabled
(configurable),
redirects to 443
HTTPS TCP/443 Enabled
(configurable)
Yes
RSH TCP/512 Disabled
(configurable)
Yes Only available
through two
management
interfaces.
TFTP UDP/69 Disabled
(configurable)
No Only available
through two
management
interfaces.
SFTP TCP/22 Enabled Yes Only available
through two
management
interfaces.
SNMP UDP/161 Disabled
(configurable)
Yes Only available
through two
management
interfaces.
SNTP UDP/123 Enabled
(configurable)
No Only available
through two
management
interfaces.
SSH TCP/22 Enabled Yes Only available
through two
management
interfaces.
ICMP Enabled No
TACACS+ TCP/49
(configurable)
Disabled
(configurable)
Yes
RADIUS UDP/1812 to send
(configurable),
opens random port
to listen to
Disabled
(configurable)
Yes Only available
through two
management
interfaces.
Remote Syslog UDP/514
(configurable)
Disabled
(configurable)
No Only available
through two
management
interfaces.
TCP Modbus (Server) TCP/502 Disabled
(configurable)
No Only available
through two
management
interfaces.
TCP Modbus (Switch) TCP/502 Disabled
(configurable)
No
DHCP, DHCP Agent UDP/67, 68 sending
msg if enabled - if
received, always
Disabled
(configurable)
No

Table of Contents