EasyManuals Logo

Siemens RUGGEDCOM ROS v4.3 User Manual

Siemens RUGGEDCOM ROS v4.3
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
RUGGEDCOM ROS
User Guide
Chapter 1
Introduction
Available Services by Port 11
Services Port Number
Service Enabled/
Disabled
Access Authorized Note
management
interfaces.
HTTP TCP/80 Enabled
(configurable),
redirects to 443
—
HTTPS TCP/443 Enabled
(configurable)
Yes
RSH TCP/512 Disabled
(configurable)
Yes Only available
through two
management
interfaces.
TFTP UDP/69 Disabled
(configurable)
No Only available
through two
management
interfaces.
SFTP TCP/22 Enabled Yes Only available
through two
management
interfaces.
SNMP UDP/161 Disabled
(configurable)
Yes Only available
through two
management
interfaces.
SNTP UDP/123 Enabled
(configurable)
No Only available
through two
management
interfaces.
SSH TCP/22 Enabled Yes Only available
through two
management
interfaces.
ICMP — Enabled No
TACACS+ TCP/49
(configurable)
Disabled
(configurable)
Yes
RADIUS UDP/1812 to send
(configurable),
opens random port
to listen to
Disabled
(configurable)
Yes Only available
through two
management
interfaces.
Remote Syslog UDP/514
(configurable)
Disabled
(configurable)
No Only available
through two
management
interfaces.
TCP Modbus (Server) TCP/502 Disabled
(configurable)
No Only available
through two
management
interfaces.
TCP Modbus (Switch) TCP/502 Disabled
(configurable)
No
DHCP, DHCP Agent UDP/67, 68 sending
msg if enabled - if
received, always
Disabled
(configurable)
No

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROS v4.3 and is the answer not in the manual?

Siemens RUGGEDCOM ROS v4.3 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROS v4.3
CategoryWireless Router
LanguageEnglish

Related product manuals