EasyManuals Logo

Siemens RUGGEDCOM ROS v4.3 User Manual

Siemens RUGGEDCOM ROS v4.3
266 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
RUGGEDCOM ROS
User Guide
Chapter 1
Introduction
SNMP Traps 15
Trap MIB
fallingAlarm
lldpRemoteTablesChange LLDP-MIB
The device also generates the following proprietary traps:
Table:Proprietary Traps
Trap MIB
genericTrap
powerSupplyTrap
swUpgradeTrap
cfgChangeTrap
weakPasswordTrap
defaultKeysTrap
RUGGEDCOM-TRAPS-MIB
Generic traps carry information about events in their severity and description objects. They are sent at the same
time an alarm is generated for the device. The following are examples of RUGGEDCOM generic traps:
NOTE
Information about generic traps can be retrieved using the CLI command alarms. For more
information about the alarms command, refer to Section2.6.1, “Available CLI Commands” .
Table:Generic Traps
Trap Severity
heap error Alert
NTP server failure notification
real time clock failure Error
failed password Warning
MAC address not learned by switch fabric Warning
BootP client: TFTP transfer failure Error
received looped back BPDU Error
received two consecutive confusing BPDUs on port, forcing down Error
GVRP failed to learn – too many VLANs Warning
The device generates the following traps when specific events occur:
Table:Event-Based Traps
Trap MIB Event
rcRstpNewTopology RUGGEDCOM-STP-MIB This trap is generated when the device
topology becomes stable after a topology
change occurs on a switch port.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROS v4.3 and is the answer not in the manual?

Siemens RUGGEDCOM ROS v4.3 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROS v4.3
CategoryWireless Router
LanguageEnglish

Related product manuals