Command Description
port is a comma separated list of port numbers (e.g. 1,3-5,7)
clearlogs Clears the system and crash logs.
clrcblstats [ all | port ]
Clears cable diagnostics statistics for one or more ports.
Optional and/or required parameters include:
all clears statistics for all ports
port is a comma separated list of port numbers (e.g. 1,3-5,7)
clrstpstats Clears all spanning tree statistics.
cls Clears the screen.
dir Prints the directory listing.
exit Terminates the session.
factory Enables factory mode, which includes several factory-level commands used for testing and
troubleshooting. Only available to admin users.
CAUTION!
Misuse of the factory commands may corrupt the operational state of device
and/or may permanently damage the ability to recover the device without
manufacturer intervention.
flashfiles { info filename |
defrag }
A set of diagnostic commands to display information about the Flash filesystem and to
defragment Flash memory.
Optional and/or required parameters include:
info filename displays information about the specified file in the Flash file system
defrag defragments files in the Flash file system
For more information about the flashfiles command, refer to Section2.8, “Managing
the Flash File System” .
flashleds timeout
Flashes the LED indicators on the device for a specified number of seconds.
Optional and/or required parameters include:
timeout is the number of seconds to flash the LED indicators. To stop the LEDs from
flashing, set the timeout period to 0 (zero).
fpgacmd
Provides access to the FPGA management tool for troubleshooting time synchronization.
help command
Displays a brief description of the specified command. If no command is specified, it displays
a list of all available commands, including a description for each.
Optional and/or required parameters include:
command is the command name.
ipconfig Displays the current IP address, subnet mask and default gateway. This command provides
the only way of determining these values when DHCP is used.
loaddflts Loads the factory default configuration.
login Logs in to the shell.
logout Logs out of the shell.
logs Displays syslog entries in CLI shell.
ping address { count |
timeout }
Sends an ICMP echo request to a remotely connected device. For each reply received, the
round trip time is displayed. Use this command to verify connectivity to the next connected
device. It is a useful tool for testing commissioned links. This command also includes the
ability to send a specific number of pings with a specified time for which to wait for a
response.
Optional and/or required parameters include:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens RUGGEDCOM ROS v4.3 and is the answer not in the manual?

Siemens RUGGEDCOM ROS v4.3 Specifications

General IconGeneral
BrandSiemens
ModelRUGGEDCOM ROS v4.3
CategoryWireless Router
LanguageEnglish

Related product manuals