Output Module Reference Data
2048 kHz Output Module
194 SSU-2000 User’s Guide 12713020-002-2 Revision D – April 2004
As another example, if the hex number is A501F, then the following ports are
squelched: 1 and 3 (corresponding to the A in Digit 1), 6 and 8 (corresponding to the
5 in Digit 2), 16 (corresponding to the 1 in Digit 4), and 17 through 20
(corresponding to the F in Digit 5).
Use the Alarm command to display the alarm information for a given module to
display all 2048 kHz Output module alarms, including Alarm #14, Squelching. Use
the Alarm command to provision these alarms to be Ignored or to generate a Report
Only, Minor Alarm, Major Alarm (default), or a Critical Alarm. Refer to the SSU-2000
User’s Guide for more information on using the Alarm command.
Table 8-10. Identifying Failed Ports from the Hex Digit
Hex Value
Digit 1
Digit 2
Digit 3
Digit 4
Digit 5
Port
1
5
9
13
17
Port
2
6
10
14
18
Port
3
7
11
15
19
Port
4
8
12
16
20
0––––
1–––X
2– X
3– X X
4– X
5– X X
6– X X
7– X X X
8X–––
9X X
AX X
BX X X
CX X
DX X X
EX X X
FX X X X

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals