User Changes to Factory Defaults
432 SSU-2000 User’s Guide 12713020-002-2 Revision D – April 2004
User Changes to Factory Defaults
Use Table E-11 to record any changes you make to the factory default settings.
Table E-15. User Changes to Factory Default Settings
Setting Factory Default User Changes
Communications Module Defaults
Unit Name SSU_2000
Module Information
configurations
Current Configuration = the configuration that is
currently in use
User Default Configuration = configuration the
user specifies as the default if the current
configuration is invalid or not present
Factory Configuration = the factory default
configuration
User List
configurations
Maximum of 25 users including four built-in users
EIA-232-C Port
Comm Port
Timeout
All three comm ports are set to 9600 baud,
Interactive Mode, CRLF, and Echo on
Five minutes for all (Interactive Mode). (Note: the
unit should have one user added, i.e. not in the
INITUSERTABLE state). If it is in the
INITUSERTABLE state, no timeout is applied.
No Timeout is assigned for the TL1 Mode
Ethernet IP
Address
IP Address 0.0.0.0
Gateway Address 0.0.0.0
Network Mask 255.255.255.0
Clock Module Defaults
Warmup Time 1200 seconds
Min Tau Limit 300 seconds
Max Tau Limit If 2E, 10000 seconds
If 3E, 500 seconds
Min Tau 300 seconds
Max Tau If 2E, 9000 seconds
If 3E, 450 seconds