Communications Module Default Settings
422 SSU-2000 User’s Guide 12713020-002-2 Revision D – April 2004
Communications Module Default Settings
Table E-1 lists settings and factory defaults for the SSU-2000 Communications
Module.
Stratum 2E and 3E Clock Module Default Settings
The Stratum 2E and 3E Clock module are software configurable via one of the serial
or Ethernet ports.Table E-2 lists settings and factory defaults for the Clock module.
Table E-1. Communications Module Factory Default Settings
Setting Factory Default
Unit Name SSU_2000
Module Information
configurations
Current Configuration = the configuration that is currently in use.
User Default Configuration = configuration the user specifies as the
default if the current configuration is invalid or not present.
Factory Configuration = the factory default configuration
User List configurations Maximum of 25 users including four built-in users.
EIA-232-C Port
Comm Port Timeout
All three comm ports are set to 9600 baud, Interactive Mode, CRLF, and
Echo on
Five minutes for all (Interactive Mode). (Note: the unit should have one
user added; that is, not in the INITUSERTABLE state). If it is in the
INITUSERTABLE state, no timeout is applied.
No Timeout is assigned for the TL1 Mode.
Ethernet IP Address IP Address 0.0.0.0
Gateway Address 0.0.0.0
Network Mask 255.255.255.0
Table E-2. Stratum 2E and 3E Clock Module Default Settings
Setting Factory Default Range
Warmup Time 1200 s 900 to 3600 s
Min Tau Limit 300 s Constant
Max Tau Limit 2E: 10000 s
3E: 500 s
Constant
Min Tau 1000 s
In the range specified in Min/Max Tau limits
Max Tau If 2E, 9000 s
If 3E, 450 s
In the range specified in Min/Max Tau
limits