12713020-002-2 Revision D – April 2004 SSU-2000 User’s Guide 229
Hardware Configuration Guide
Configuring a Subtending SSU
Output modules are available to support the following formats:
DS1, SF (D4) and ESF
E1, CAS, and CCS
2048 kHz
Composite Clock (CC) (64/8 kHz)
Other typical clock frequencies
Setting Subtending Parameters
The SSU-2000 software includes the following new command that allows you to
enable and disable the Subtending mode. For additional information on general
syntax and usage, refer to Appendix B, Communications Protocol.
OPERMODE
This command allows you to view and change the operating mode of the
SSU-2000.
Level 0 Not applicable
Level 1 Not applicable
Level 2 Not applicable
Level 3
OPERMODE [SUBTENDING|NORMAL]
If you do not specify a parameter, the system displays the current mode.
SUBTENDING Sets the SSU to Subtending mode.
NORMAL Sets the SSU to normal TSG operation.
Level 4 Same as Level 3 operation.
Restrictions See Changing to Subtending SSU Mode, on page 230, for
hardware and software requirements.

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals