EasyManuals Logo

Symmetricom SSU-2000 User Manual

Symmetricom SSU-2000
470 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #249 background imageLoading...
Page #249 background image
12713020-002-2 Revision D – April 2004 SSU-2000 User’s Guide 249
Alarm Messages
Table A-4. LRM Alarm Messages
Alarm
Description
Alarm
Number
Default
Alarm
Level
Status
Messages
Range
Description/
Corrective
Action
Side 1 Loss of
signal fault status
0Minor
Ok
Fault
Minor Verify signal is
connected. Can be
cleared by disabling
port.
Side 1 Alarm
indication signal
fault status
1 Report
Ok
Fault
Ignore
Report
Minor
Verify input signal is
good. Port can be
disabled.
Side 1 Loss of
frame signal fault
status
2 Report
Ok
Fault
Ignore
Report
Minor
Change frame type:
D4
ESF
Side 1 Bipolar
violation signal fault
status
3 Report
Ok
Fault
Ignore
Report
Minor
Verify port ZS is on.
Verify signal is good
Side 1 Slip signal
fault status
4 Report
Ok
Fault
Ignore
Report
Minor
Accumulated slip
value exceeded
threshold setting
Side 2 Loss of
signal fault status
5 Report
Ok
Fault
Ignore
Report
Verify signal on side
2 is connected. Can
be cleared by
disabling port.
Reference PLL
fault
10 Minor
Ok
Fault
Minor Verify clock reference
source is good.
Reference PLL is
unlocked
CTA Fuse 11 Minor
Ok
Fault
Ignore
Report
Minor
Verify CTA fuse is
good
CTA 12 Minor
OK
Fault
Ignore
Report
Minor
CTA present/not
present
Mismatch Dual/Quad

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals