12713020-002-2 Revision D – April 2004 SSU-2000 User’s Guide 429
2048 kHz Output Module Default Settings
2048 kHz Output Module Default Settings
The 2048 kHz Output module maintains factory default and current user
configuration settings. The configuration settings for the 2048 kHz Output Module
are provided in Table E-10.
E1/2048 kHz Output Module Default Settings
The
factory default setting and range for all E1/2048 kHz Output module software
parameters are listed in
Table E-11
.
Table E-10. 2048 kHz Output Module Configuration
Setting Factory Default Range
Port State Disabled Disabled/Enabled
Min Clock Acquire Acquire/Lock
Framing Not applicable Not applicable
Zero Suppression Not applicable Not applicable
CRC Not applicable Not applicable
SSM Not applicable Not applicable
PQL 4 Not applicable
Bypass On On/Off
Fault Action On Off/On/Auto
Table E-11. E1/2048 kHz Output Module Configuration
Configuration Setting Factory Default Range
Port State Enabled Disabled/Enabled
Bypass On On/Off
Signal Type E1 E1/2048
Zero suppression On On/Off
Squelching 0 1–16, 0 is disabled

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals