12713020-002-2 Revision D – April 2004 SSU-2000 User’s Guide 257
Event Messages
SNMP Trap, ALM, COML\ 206 The SNMP Trap Port has been set to send
traps on alarms only by the user
Chg KeepAlive, ALL, 15 minute, COML\ 207 The Keep Alive timer has been set to the
interval shown
Err Delay, (1), 300 sec, COML\ 251 An alarm delay time change
Alm Level, (2), Rep, COML\ 252 An alarm level change
Elevate Time, 3600 sec, COML\ 253 An alarm elevation time change
Setup, Save, COML\ 254 User defaults change or save
Table A-8. Input Module Event Messages
Event Message Event # Event Description
DS1/E1 Input Module Events
Install, Input Module\ 129 Module Installation
Remove, Input Module\ 130 Module Removal
Enable, Input Module, COML\ 131 The Input module has been enabled
Disable, Input Module, COML\ 132 The Input module has been disabled
Restart, in 5 seconds, COML\ 133 Module re-boot
Cannot Enable, Input Module, COML\ 134 Internal firmware conflict. Restart module, if
the problem persists, call Symmetricom
Global Services
Zero Phase, B, COML\ 144 User has forced the phase to be cleared
Rcv Pql Chg, 3\ 145 Input has received a different PQL
Pha Buildout, 334000, 335000\ 146 Input performed phase buildout and
difference in Phase that cause PBO
DS1 Framer, ESF, COML\ 193 An Input framer setup change
E1 Framer, CCS, COML\ 194 An Input framer setup change
Freq, 10 MHz, COML\ 195 User changed input framer setup
ZS, On, COML\ 196 User changed input framer setup
SSM, Off, COML\ 197 User changed input SSM capability
CRC, On, COMl\ 198 User changed input framer setup
Table A-7. Communications Module Event Messages (Continued)
Event Message Event # Event Description