12713020-002-2 Revision D – April 2004 SSU-2000 User’s Guide 217
Output Module Reference Data
Line Retiming Unit (LRU)
Provisioning the LRM
The following information provides examples of how to use ICS and TL1 commands
to provision an LRM in an SSU-2000. Refer to TL1 Command Interface, on page
266, and Interactive Command Set, on page 315, for details on ICS and TL1
commands.
Examples
The following ICS commands enable port 2 on an LRM in slot 8 of shelf 3, set the
line build-out to 399 feet, and set the slip error threshold to 6:
LRM 3A8-2 ENABLE then press Enter
LRM 3A8-2 LBO 399 then press Enter
LRM 3A8-2 SLIP 6 then press Enter
SET-PRMTR-LRM::S3A8-2:::ON,399,6,,;
The following ICS commands enable port 3 of an LRM in slot 11 of shelf 2 and
enables a FAULT strategy,:
LRM 2A11-3 FLT AIS then press Enter
SET-PRMTR-LRM::S2A11-3:::ON,,,,,AIS;
The following ICS commands set the circuit ID of port 4 on an LRM in slot 7 of shelf
1 to 1A7-4:
LRM 1A7-4 CID 1A7-4 then press Enter
SET-PRMTR-LRMCID::S1A7-4:::1A7-4;
Alarms and Events
The LRM generates the alarms and events listed in Table A-4 and Table A-9,
respectively.

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals