12713020-002-2 Revision D – April 2004 SSU-2000 User’s Guide 247
Alarm Messages
Hardware
configuration fault
14 Major Ok
Failed
Call Symmetricom Global
Services. Return to
factory.
GPS Input Module Alarms
Hardware
configuration fault
0Major
Ok
Failed
Call Symmetricom Global
Services. Return to
factory.
GPS Engine
tracking status
1 Minor
Ok
Not Tracking
No visible satellites seen
at startup.
Antenna
connection status
2 Minor
Ok
Not Connected
Verify that:
The antenna is
connected
The cable and
connectors are not
damaged
The antenna is placed
correctly
Antenna condition
fault
3 Minor
Ok
Shorted
Ring out the cable to
ensure that the center
conductor is not shorted
to the sleeve, then verify
that:
The antenna cable is
connected properly
The cable and
connectors are not
damaged
GPS Engine
hardware fault
4 Minor
Ok
Bad
Reseat module. If
problem persists, call
Symmetricom Global
Services.
Engine system fault 5 Minor
Ok
Bad
If alarm doesn’t clear
after 30 minutes, call
Symmetricom Global
Services.
Position unknown
fault
6 Minor
Ok
Unknown
If alarm doesn’t clear
after 1 hour, call
Symmetricom Global
Services.
Table A-3. Input Module Alarm Messages (Continued)
Alarm
Description
Alarm
Number
Default
Alarm
Level
Status
Messages
Description/
Corrective Action

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals