12713020-002-2 Revision D – April 2004 SSU-2000 User’s Guide 329
Interactive Command Set
This command displays the input adapter part number and its
description for each Input module. This command is valid only if the
SSU-2000 software and hardware support this function.
Level 2 Same as Level 1 operation, with the following additions:
CONFIG xAy {REMOVE|DISABLE|ENABLE}
Options are:
REMOVE Use this option to remove module entries from the
registry. A module is removable only if it is physically
absent.
DISABLE Use this option to mark a module inactive to be
removed from the system.
ENABLE Use this option to restore a previously disabled module
to be active in the system.
Level 3 Same as Level 2 operation
Level 4 Same as Level 3 operation
Remarks None
Related VER
Restrictions None
The following are examples of the
CONFIG command message format:
Example 1
SSU_2000->CONFIG
2001-06-21T15:10:34Z ID: SSU2000 Name: JWANG
Loc# Name HW Part # HW Rev Date Serial #
---- -------------------- -------------- -------- ------- ------------------
1 SSU-2000 25413020-000-0
1A01 Clock Stratum 2E 23413016-000-0 A 30NOV99 990705398000615020
1A02 Communication 23413012-000-0 A 03NOV99 990705398000614573
1A03 Input GPS 23413019-000-0 A 18DEC99 1234567890005
1A05 Input GPS 23413019-000-0 A 29FEB00 990705398000728324
1A06 Input E1 3Port 23413014-002-0 B 03DEC99 990705398000661713
1A07 Input DS1 3Port 23413013-002-0 B 26JAN00 1234567890
1A08 Input DS1 1Port 23413013-001-0 B.02 21APR00 990705398000736077
1A09 Input DS1 3Port 23413013-002-0 B.02 27MAR00 990705398000736527
1A10 Output DS1 23413017-000-0 D 30NOV99 990705398000613606
1A11 Output DS1 23413017-000-0 B 02MAR00 990705398000613453
1A12 Clock Stratum 3E 23413015-000-0 A 09MAR00 990705398000734493
2 SDU-2000 25413023-000-0
2A01 Output E1 23413018-000-0 D 05JAN00 990705398000650816
2A02 Output E1 23413018-000-0 D 13JAN00 990705398000650793
2A03 Output DS1 23413017-000-0 D 15JAN99 1234567890
2A04 Output DS1 23413017-000-0 D 15JAN99 1234567890