EasyManuals Logo

Symmetricom SSU-2000 User Manual

Symmetricom SSU-2000
470 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #339 background imageLoading...
Page #339 background image
12713020-002-2 Revision D – April 2004 SSU-2000 User’s Guide 339
Interactive Command Set
FREQUENCY
Use this command to display the input frequency data from a selected input port.
Level 0 Not applicable
Level 1
FREQUENCY [xAy][{A|B}]
Use this command to view the frequency measurement from a
selected input module. If you do not provide a parameter,
frequency measurement on the selected clock to all inputs
displays.
Options are:
A|B Clock A or Clock B
Level 2 Same as Level 1 operation
Level 3 Same as Level 1 operation
Level 4 Same as Level 1 operation
Remarks None
Related INPUT, PHASE
Restrictions None
Example:
SSU_2000->FREQUENCY
1A04-01 FreqA:2001-06-18T20:54:19, 0
1A04-02 FreqA:2001-06-18T20:54:19, 1
1A04-03 FreqA:2001-06-18T20:54:19, 1
1A09-01 FreqA:2001-06-18T20:54:19, 3
1A09-02 FreqA:2001-06-18T20:54:19, 2
1A09-03 FreqA:2001-06-18T20:54:19, 1

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals