EasyManua.ls Logo

Trilithic 180 DSP - Bit-Error Rate; Hum (Optional

Trilithic 180 DSP
386 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.trilithic.com
Page IV-28
180 DSP Operation Manual
Signal Level Meter
Bit-Error Rate
Select the BER button from the
Display pop-up menu to display the
BER on a graph with a 150 second
measurement period with solid green
lines for Pre BER and solid red lines
for Post BER.
The following measurement results
are displayed with a pass/fail status for
each measurement that is included in
the open limit set:
Digital channel level value with bar graph
Pre BER
Post BER
Errors per second
Service errors
HUM (OPTIONAL)
When activated in a 180 DSP, the HUM feature provides users with the ability to
measure the amplitude of the 50/60 Hz, 100/120 Hz, and low frequency interference
present on the QAM carrier of a single selected digital channel.
Select the Hum button from the
Display pop-up menu to display a bar
graph of the HUM levels of the QAM
channel.
The following measurement results
are displayed with a pass/fail status for
each measurement that is included in
the open limit set:
60 Hz level value with bar graph
120 Hz level value with bar graph
< 1 kHz (low frequency) level value with bar graph

Table of Contents