Dismounting inlet valve, connecting hose and water filter
Procedure Follow this procedure to dismount the inlet valve and the connecting hose:
Step Action Illustration
1.
Open the cabinet door, turn off machine (main switch), unplug the
power supply plug and close the water cock.
2.
Remove waste bucket (only FB).
3.
Remove waste tray.
4.
Remove protective cover.
5.
Remove inlet valve from inlet
valve holder.
NB. The inlet valve holder is
mounted on the back inner
wall.
6. Unscrew connecting
hose (1).
Unscrew water filter
from inlet valve (2).
Unscrew filter lid (3).
Dismount inlet valve
(4).