November, 1998
16
Dismounting/Repair Brewing SystemService Manual FB50/55/5100/5500
Fig. 3
9.2.10Dismounting the Actuator
When dismounting the actuator, the
driving parts (tacho disc) must not
be dismounted first.
Release the actuator spring (1) by turning
the fastening nut of the tacho disc (2) anti-
clockwise. The nut must rotate together with
the tacho disc and must not loosen. (Fig. 1)
Remove the bearing housing (3) and the
spring (4). (Fig. 2)
In order to remove the tacho disc, it must
be fixed. (Fig. 3)
Now unscrew the nut (5). (Fig. 3)
Hold the large gear wheel (6) tightly and
remove the nut. (Fig. 3)
Fig. 1
Fig. 2
2
1
4
3
6
5