Dismounting the vending machine controllers
Procedure Follow this procedure to dismount the vending machine controllers:
Step Action Illustration
1.
Open the door.
2.
Switch off the main switch, disconnect the power supply plug and close the
water cock.
3.
Remove all canisters.
4.
Remove cover plates by
loosening screws (1).
5.
Disconnect all cable connections.
6.
Press the fastening clips together.
7.
Remove the vending machine
controllers to the front.
8.
Mount the boards in reverse order.
9.
Remount cover plates.