November, 1998
26
Dismounting/Repair Brewing SystemService Manual FB50/55/5100/5500
3. Remove the jack latch (6) from the filter
plate. Decalcify all metal parts of the filter
plate. (Fig. 4)
4. Clean the rubber sealing (7), the sealing
ring (5), and the filter plate holder in hot
water. (Fig. 3, 4)
5. Install the filter plate in reverse order. Make
sure that the locking bolt engages, and that
the filter plate is guided by the scraper
arms.
Make sure that the disc (8) is positioned
correctly.
(The smooth side must face the sealing).
(Fig. 4, 5)
Avoid damage of the fine-pore filter.
Fig. 4
6
8
7
5
Fig. 5