2
Water l. low Water tank is not filled
within 3 minutes
Inlet valve defective
Blocked water filter
Water supply connection
blocked
Switch machine off, open water cock,
check water connection and hoses
Check, replace if necessary
Remove impurities and clean / replace, if
necessary.
Remove impurities.
Temp. low Water temperature is too
low
Heating element defective
Harness for heating ele-
ment defective
Machine has just been
switched on
Harness for temperature
sensor defective
Wait until the water is heated sufficiently
(approximately 15 minutes)
Check the heating element, replace it if
necessary.
Check harnes, replace if necessary.
The display is automatically cleared when
the water in the tank reaches the correct
temperature.
Check, replace if necessary.
Heater error
(IN, FB only)
Over boil thermostat has
triggered
Over boil thermostat is de-
fective
Harnes for overboil ther-
mostat is defective
Temperature sensor is de-
fective
Harness for temperature
sensor defective
Press the reset button
Check the boil over switch, replace it if
necessary
Check, replace it if necessary
Check, replace it if necessary
Check, replace it if necessary.
Energy save Energy save period is on Change energy save period
Check the clock, make sure that the time
is correct.
Bucket full Drip tray full
Drip tray sensor defective
Harnes for drip tray sensor
defective
Leak in machine
Waste bucket full
Waste bucket sensor de-
fective
Harness for waste bucket
sensor defective
Switch machine off, empty drip tray and
dry the water level sensor
Check, replace it if necessary
Check, replace it if necessary
Check and repair it
Switch machine off, empty waste bucket
and dry the sensor
Check , replace it if necessary
Check, replace it if necessary
Brewer error Brewer blockage
Brewer defective
Brewer motor defective
Harnes for brewer motor
defective
Defective harnes between
MC and switches
Micro switches maladjust-
ed
Empty waste bucket
Switch machine off/on
Check brewer and brewer connections,
adjust, repair or replace defective part if
necessary.
Fault Possible cause Remedy

Table of Contents