7.5.1 Application Constants: b
Advanced Operation
7-50
D
Integral (I) Limit: b5-04
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit
Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
b5-04
Integral (I) limit
f
0.0 to 100.0 % 100.0
A A A A
This constant prevents the calculated value of the integral control in the PID control from exceed-
ing the fixed amount.
There is normally no need to change the setting.
Reduce the setting if there is a risk of load damage, or of the motor going out of step, by the Invert-
ers response when the load suddenly changes. If the setting is reduced too much, the target value
and the feedback value will not match.
Set this constant as a percentage of the maximum output frequency, with the maximum frequency
taken as 100%.
D
PID Limit: b5-06
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit
Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
b5-06
PID limit
f
0.0 to 100.0 % 100.0
A A A A
Constant b5-06 prevents the frequency reference after PID control from exceeding the fixed
amount.
Set this constant as a percentage of the maximum output frequency, with the maximum frequency
taken as 100%.
D
PID Offset Adjustment: b5-07
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit
Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
b5-07
PID offset adjust-
ment
f
100.0 to
100.0
% 0.0
A A A A
Constant b5-07 adjusts the PID control offset.
If both the target value and the feedback value are set to zero, adjust the Inverters output frequency
to zero.
D
PID Primary Delay Time Constant: b5-08
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit
Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
b5-08
PID primary delay
time constant
f
0.00 to
10.00
s 0.00
A A A A
Constant b5-08 is the low-pass filter setting for PID control outputs.
There is normally no need to change the setting.
If the viscous friction of the mechanical system is high, or if the rigidity is low, causing the mechan-
ical system to oscillate, increase the setting so that it is higher than the oscillation frequency period.
This will decrease the responsiveness, but it will prevent the oscillation.
J
PID Output Characteristics: b5-09 (for SPEC: F)
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit
Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
b5-09
PID output charac-
teristics
×
0, 1 0
A A A A
D
Settings
Setting Function
0
PID output has forward characteristics
1
PID output has reverse characteristics
7