11.1 Standard Inverter Specifications
11 - 3
Model number
CIMR-G5A
20752055204520372030202220182015201127P525P523P722P221P520P720P4
Motor protection
Protection by electronic thermal overload relay.
Instantaneous over-
current protection
Stops at approx. 200% of rated output current.
Fuse blown protec-
tion
Stops for fuse blown.
Overload protection
Stops in one minute at approx. 150% of rated output current.
ctions
Overvoltage protec-
tion
Stops when main-circuit DC voltage is approx. 406 V.
ive fun
Undervoltage protec-
tion
Stops when main-circuit DC voltage is approx. 190 V.
rotecti
Momentary power
loss ridethru
Stops for 15 ms or more. By selecting the momentary power loss mode, operation can be continued if power is restored within 2 s.
P
Cooling fin overheat-
ing
Protection by thermistor.
Stall prevention
Stall prevention during acceleration, deceleration, or running.
Grounding protection
Protection by electronic circuits. (Overcurrent level)
Charge indicator (in-
ternal LED)
Lit when the main circuit DC voltage is approx. 50 V or more.
Ambient operating
temperature
−10° to 40°C (Enclosed wall-mounted type)
10° to 45°C (Open chassis type)
ent
Ambient operating
humidity
90 % RH max.
ronm
Storage temperature
−20 °C to +60 °C
Envir
Application site
Indoor (no corrosive gas, dust, etc.)
Altitude
1000 m max.
Vibration
10 to 20 Hz, 9.8 m/s
2
(1G) max.; 20 to 50 Hz, 2 m/s
2
(0.2G) max
* 1. The maximum applicable motor output is given for a standard 4-pole Yaskawa motor. When selecting the actual motor and
Inverter, be sure that the Inverter’s rated current is applicable for the motor’s rated current.
* 2. Tuning is sometimes required.
Table
11.2
400 V Class Inverters
Model number
CIMR-G5A
40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4110 4160 4185 4220 4300
Max. applicable motor
output (kW)
0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 110 160 185 220 300
Rated output capac-
ity (kVA)
1.4 2.6 3.7 4.7 6.1 11 14 21 26 31 37 50 61 73 98 130 170 230 260 340 460
gs
Rated output current
(A)
1.8 3.4 4.8 6.2 8 14 18 27 34 41 48 65 80 96 128 165 224 302 340 450 605
ut rat
n
Max. output voltage
(V)
3-phase, 380 to 460 VAC (Proportional to input voltage.)
utp
Rated output fre-
quency (Hz)
Up to 400 Hz (available by programming.)
teristics
Voltage (V)
Frequency (Hz)
3-phase, 380 to 460 VAC, 50/60 Hz
pply charac
Allowable voltage
fluctuation
+ 10%, −15%
Power su
Allowable frequency
fluctuation
±
5%
11